商场节能管理范例6篇

前言:中文期刊网精心挑选了商场节能管理范文供你参考和学习,希望我们的参考范文能激发你的文章创作灵感,欢迎阅读。

商场节能管理

商场节能管理范文1

关键词:商场建筑;能耗模拟;正交试验法;节能

Analysis on Energy Efficiency and Energy Consumption

Simulation of a Shopping Mall

XIAO Shu-ying1, SUN Rui-jun2

(1.Tianjin Chance Architecture Design Co.,LTD, Tianjin, 300074,China;

2. Tianjin ShangHeng Architecture Design Co.,LTD, Tianjin, 300221,China)

ABSTRACT: Energy simulation software named DesignBuilder was used to develop an energy consumption model of a shopping mall in Weihai. A method named orthogonal experiment is chosen to analyze and select the main factors affect the market energy consumption. And the corresponding energy-saving measures are proposed.

Keywords: emporium building; energy simulation; orthogonal experiment; energy-saving

中图分类号: TE08 文献标识码: A

0 引言

商场类建筑由于建筑面积大、营业时间长、客流密度大和用电密度高等特点,与其他类型公共建筑相比,单位面积电耗密度高且全年总能耗量大[1]。并且,随着人们对购物环境舒适性要求的不断提高,商场类建筑的能耗还会持续增加,因此商场类建筑的节能任务极其艰巨。本文以威海市某商场为例,借助DesignBuilder能耗模拟软件对商场建筑能耗进行分析,找出影响商场建筑能耗大小的主要因素,并提出商场类建筑节能的关键措施。

1 商场概况及模型的建立

1.1商场概况

该商场建筑位于山东省威海市,建于2004年,总建筑面积为34662m2,坐北朝南,主体5层,建筑高度23.8m,地下局部两层,建筑体形系数为0.11,东、西、北面墙窗墙比为0.12,南面墙窗墙比为0.40,结构形式为框架结构。该商场地下一层为超市,地上1-5层为商场卖场。冷热源形式为“冷水机组+市政热水”,空调系统形式为“全空气定风量系统”。

1.2模型的建立

该商场建筑外墙和屋面的围护结构主体构造和热工特性见表1所示:

表1 典型商场建筑围护结构主体构造和热工性能

该商场建筑室内照明设备采用悬顶式荧光灯,局部区域为突出物景效果采用白炽灯调光,部分专柜照明采用射灯。商场室内照明的运行时间与营业时间同步,为早9:00~晚22:00。室内照度设置为600lx,照明功率25w/m2。

该商场人员密度设置为0.4人/m2;商场内人员劳动类型为轻劳动,群集系数取0.9;最小新风量20m3/(hp)。

该商场室内空调温度设置为25℃,采暖温度设置为20℃。冷水机组COP设置为4.0。

在该商场建筑数字化模型建立的过程中,对模型进行了适当的简化:在保持建筑主体构造材料、建筑内扰、外扰等设定不变的情况下,对建筑每层不再进行分区,将整层作为大空间建筑处理,像楼梯间、洗手间等全部当作卖场进行参数设置。

根据上述参数进行设置,得到如图1所示的商场建筑数字化模型。

图1 典型商场建筑数字化模型

2 全年总能耗模拟结果

对该商场建筑全年逐日能耗进行模拟,模拟结果见图2所示,该商场建筑总能耗为215.88kWh/(m2a),其中电力能源消耗为199.11 kWh/(m2a),热力能源消耗为16.77kWh/(m2a)。热力能源消耗仅占总能耗的7.9%。从图中可以看出全年耗电量和耗热量的逐月变化变化趋势,耗电量在7~9月份达到峰值,在12~2月份达到谷值。

此外,模拟结果显示,该商场建筑的电力能源消耗中,照明系统耗电量、空调系统耗电量、动力系统耗电量和其他设备耗电量分别占总耗电量的比例为36.9%、49.4%、9.8%、3.9%。

该商场模型的能耗模拟结果,与实际审计得到的全年逐月耗电量、耗热量基本相符,印证了所建模型的准确性。

图2 典型商场建筑全年逐日能耗模拟图

(图中上面的曲线为电力能源消耗,下面的曲线为热力能源消耗)

3 建筑能耗主要影响因素分析

影响该商场建筑能耗大小的因素有很多, 其中的关系也比较复杂。研究该商场能耗影响因素的主次关系,从最主要“矛盾”入手进行节能改造,可以用有限的资金达到最好的节能降耗目的。本文采用正交试验法对各影响因子进行分析,以确定外墙类型、外窗类型、人员密度、照明密度、机组COP等因素对商场建筑能耗的影响。

3.1正交试验设计[2]

根据影响建筑物能耗的因素,取外墙类型、外窗类型、屋顶类型、人员密度、照明密度(包括商品展示照明)、制冷机组COP值以及是否遮阳7个指标。本试验主要目的是定性的考察因子显著性,而不是定量考察因子的影响规律,故而对每个因子只选取两个水平进行考察,设计7个因子2个水平的正交试验,用型的正交试验表格。

正交模拟因子的取值见表2所示:

表2 各因子不同水平的取值

表2 中水平1代表该商场建筑现有水平,水平2取值部分参考《公共建筑节能设计标准》GB 50189-2005中的相关规定。由于水平1、2室内设计温度均为25℃,故在正交试验安排中,没有把室内设计温度作为因子来考虑。

借助能耗模拟软件对商场建筑模型各个试验进行模拟分析,试验模拟结果见表3第9列所示。

3.2试验分析

表3为模拟结果直观分析表,从结果可以看出,照明密度因素对应的极差最大,远大于其它各项因素,说明照明密度对全年能耗的影响最大,是最关键因素,照明设备不仅本身要耗能,而且其散发到空气中的热量又间接影响空调负荷,导致夏季空调能耗也随之增加;而各种围护结构所对应的极差都较小,说明围护结构对夏季总冷负荷的影响为次要因素。因此,对于该商场建筑,采用直观分析法根据极差大小,对各因素影响建筑总能耗程度的排序为:照明密度>人员密度>机组COP>外窗类型>是否遮阳>外墙类型>屋顶类型。这里还需要说明的是这种排序不是固定的,当试验条件变化时它们之间的排序也要变化。

表3不同方案能耗模拟结果及直观分析表

4 该商场建筑节能途径举例

4.1照明系统节能

从正交试验分析得到的结论来看,照明密度是最显著因子,因此,在不影响室内亮度的前提下如何降低照明能耗是该商场节能的重点之一。商场应尽可能采用高效节能的照明灯具,这样不仅能使照明系统能耗降低,还能减小空调热负荷从而减少空调系统的能耗。商场内若采用高效节能的紧凑型荧光灯或细管荧光灯等灯具,在相同的亮度下,耗电量是普通白炽灯的25%,是普通荧光灯的90%[1]。

4.2空调系统节能

空调系统的运行能耗是该商场建筑总能耗中另一所占比例较高的部分,对于空调系统的节能措施,可以兼顾运行与管理节能,从以下两方面入手:

1.技术方面:优化温度设定值,选择合理的室内空调运行参数;提高空调系统自动化和智能化控制程度;利用可再生能源;合理选择冷热机功率,提高冷热源效率。

2.管理方面:充分运用分项计量、能耗审计等得到的能耗结果,有针对性的采用合同能源管理或节能目标管理等管理措施,形成及时发现问题并及时加以解决的管理体系,实现系统的长期节能运行。

4.3围护结构节能

该商场是在《公共建筑节能设计标准》(GB 50189-2005) 颁布实施之前修建的,其护结构很多都没有达到标准的相关要求。

外墙方面:相同厚度下挤塑聚苯板(XPS)的保温性能要高于膨胀聚苯板(EPS)和胶粉聚苯颗粒;在同种材料、相同厚度的情况下,外保温优于内保温[3]。因此应积极采用并推广外墙外保温技术,保温材料首选XPS。

外窗方面:目前双层中空玻璃窗应用较为广泛,窗框型材主要有塑钢和断热铝合金两种。如果采用同样的玻璃系统,塑钢窗的保温性能略优于断热铝合金窗[4],但后者在抗风压强度和水密性等综合方面有明显优势。玻璃方面,推荐使用隔热性能和光学性能良好的LOW-E玻璃。

5 结论

1.通过对威海市某商场建筑能耗进行模拟分析,得出商场建筑热力能耗消耗与其他类型公共建筑相比要小的多,仅占总能耗的7.9%;该商场建筑空调系统、照明系统和动力系统耗电量分别占总耗电量的49.4%、36.9%和9.8%。

2.采用正交试验法并借助能耗模拟软件对影响该商场建筑能耗的因素进行主次排序,顺序为:照明密度>人员密度>机组COP>外窗类型>是否遮阳>外墙类型>屋顶类型。

3.空调系统和照明系统能耗占到了该商场总能耗的86.3%,因此从这两方面着手进行节能改造,是降低该商场总能耗最关键的因素。

参考文献

[]王雷,姚文燕.重庆商场类建筑能耗特性及节能措施分析[J].浙江建筑, 2008,25(5):52-54

[2]高允彦. 正交及回归试验设计方法[M].冶金工业出版社,1988,5

商场节能管理范文2

引言

我是世界上能源消费大国,其中供暖空调能耗是导致我国出现季节性能源短缺的主要原因。目前我国大部分地区出现的能源供需矛盾都是季节性的能源短缺,而不是全年性的能短缺,尤其是电力和天然气。据悉,我国在采暖和空调上能耗占建筑总能耗的55%。而作为建筑能耗最主要构成部分的供暖和空调能耗属于季节性能耗,并且许多情况下冬季供暖和夏季空调消费的能源品种不同,这是导致电力、煤炭、天然气出现季节性能源短缺的主要原因。同时随着居民对夏季空调和冬季供暖舒适性水平要求的日益提高,由此引起的城市能源季节性供需矛盾日益突出,并且已经成为制约我国经济社会可持续发展的瓶颈。然而社会发展到今天,不论是工业建筑还是公共建筑,如影剧院、体育馆、办公楼、商场、店铺等都已经离不开空调。因引节能和带能量回收的空调产品已成为当今社会发展的需要。同时,大型商场具有很大的空调节能潜力,正确设置冬、夏天室内温度能产生良好的节能效果,因为冬天室内温度设定值每升高1摄氏度,夏天室内温度设定值每降低1摄氏度,平均将多消耗10%的能耗。但是我国当肖的大型商场室内温度常常存在夏天设定过低,冬天设定过高的现象,造成能源大量浪费。

1、大型商场内空调负荷的特点

我国大型商场建筑自从八十年代以来进入了一个高速发展期,特别是近20年来,大型商场和以前相比有了很大的变化。一方面,大型商场经营的商品种类多,品种全,规模大,客流量大;大型商场的功能更多、更齐全,很多大型商场内设置了餐厅,电影院,酒吧,展厅等休息娱乐的分区;另一方面,对于消费者来说,逛商场的目的不仅是为了购买商品,还成为了一种休闲娱乐的方式。正是由于大型商场以上的特点以及消费者观念的转变,带来了大型商场的空调负荷的复杂性和多样性。

大型商场的空调负荷主要分为围护结构的传热负荷,商场内部的照明发热量,人员负荷,新风负荷等。大型商场建筑面积大,内部空间大,体形系数大;而且目前很多大型商场为了外观,采用大面积的玻璃幕墙,导致通过围护结构的负荷巨大;商场经营的商品种类繁多,内部分区和展示商品的柜台多,由此导致商品展示的照明也增多,再加上商场内的日常照明,从而使得商场内的照明能耗和照明带来的负荷也增多;大型商场内人流量很大,且随着时间的不同人流密度还有很大的变化,一般在下午和晚上人流量达到最大值,从而使得商场内人员热湿负荷大,且不同时间热湿负荷还有很大的差别。

2、 节能改造措施

近年来,已有很多大型商场对能耗过高的空调系统进行了节能改造,也有不少研究者对大型商场空调系统的节能改造进行了研究。其中对空调箱风机、输水泵以及冷却塔进行变频控制是空调系统节能改造的主要措施和策略;大型商场的节能改造除了针对能耗大以外,还针对商场内的不令人满意的热舒适性,相应的手段一般都是对风系统,包括新风系统和排风系统进行改造。

2.1排风热回收

大型商场需要送入大量新风,必然有等量的室内空气排出,夏季排风含有一定的冷量。商场往往采用机械排风这种有组织的形式。如果在排风中设置热交换装置,最多可节约新风能耗70%左右。

排风热回收设备大致可以分为两类:全热型热回收和显热型热回收。全热回收器不同于显热回收器的地方在于前者同时回收排风中的能量和湿量,是靠新风与排风的温差和水蒸汽压力差来达到热湿交换,其进出口关系可以由温度效率和湿度效率确定,效率值与新风量、排风量大小有关;而显热回收器则仅仅是温差的热交换。

全热型热回收的工作原理是利用室内外空气的焓差,利用机芯的导热透湿功能,新风获取排风中的焓值,达到节约冷量的目的。常用的有转轮式全热交换器和板翅式全热交换器。全热交换的热效率一般在65%~80%之间。显热型热交换只有热交换而无湿交换,常用的有板翅式显热交换器和轮道式等。另外,还有采用热泵来回收排风中的能量。在设计热回收方案时有一下几点建议:

应考虑商家的利益,空调机房面积总是被限制,空间利用率有限,而且室外进风口和排风口的距离要求尽量间隔远,避免气流短路。由于城市空气质量较差,积灰现象较严重,过滤器易堵塞,应设计过滤器压差开关装置,提示用户清洗或更换过滤器。

能量回收必要条件是新风系统与排风系统布置在一处,这就要求设计时对系统划分、风道布置、送排风机和热回收装置的设备等统筹安排,使系统趋于合理。

热交换器的大小是按空调供冷或供暖时的最小风量确定的。必须注意的是过渡季节或冬季采用新风供冷时不能用热交换器,因为新风被排风加湿、换热后,会降低新风供冷的效果。所以过渡季节能量回收器不运行的系统采用新风供冷时,应在新风道和排风道上分别设旁通风道,使空气绕过热交换器,以节省能耗。

至于到底选用哪种热交换器应该根据当地气候、建筑类型、热交换热备自身的特点和经济发展状况等综合分析后决定。该商场位于夏热冬暖地区,设计中采用了全热

2.2 风系统与节能

变频控制是目前送风系统节能改造的主要策略。大型商场内的热湿负荷随时间变化有很大的变化,然而送风系统却是一直高负荷运行,造成很大的浪费;且随季节的不同,送风量也有不同,特别是新风量有很大的变化,冬夏季只需要提供卫生的最小新风量,而过度季节需要更多的新风来除去余热余湿,从而减少机组运行时间,降低能耗。因此,在合理设计新风系统时,应根据实际的需要来对风机转速进行调节,风机的变频运行可以实现这一目的。在保证最小风量的情况下,利用传感器测得的送回风的干湿球温度,计算送回风焓差,从而计算出所需的风量,对风机实行变频控制;对空调系统的节能改造中,对现有的风机加装4个变频柜,对风机进行变频控制。

2.3增加自控装置

调研中发现目前空调系统的自控系统很差,如果对自控系统进行改进,也可以节约大量能源,具体可在如下方面进行改进:(1)送风机与新、回风电动阀联锁运行,当送风机根据冷负荷的变化而变频运行时可以联动调节新回风的混合比;(2)停机时回风阀全开,新风阀全关,以避免停机时夏季室外热空气继续进入室内而造成冷量损失;(3)据实际冷热负荷控制冷水机组及水泵的运行台数,以达到节能效果;(4)风机与冷冻水阀联锁,风机停时,冷冻水阀自动关闭;(5)通过时间程序对空调机进行定时启停,时间预定可长达一年;(6)可以根据现场的具体情况和用户的要求,对这些程序中的参数及连锁点进行修改和设定;(7)根据室内设定温度控制回风和新风的比例,调节合适的新风阀和回风阀开度,以保证在四季能提供足够的新风量,而在新风温度接近室内温度设定时,尽量引入新风,使其达到节能之功效;(8) 在组合式空调机组的回风总管和新风机组送风总管上分设温度传感器,也就是使过滤后的混合风温度保持在新风温度与回风温度的某一加权平均值,其所测风温与设定值比较后输出电信号,调整回水管比例积分电动调节阀的开度,调节水流量,保证回风温度在设定的波动范围内。

2.4定期的检查和检修

在对商场各层送回风口温度的检测中(如图5),发现有的送回风口温度偏高,有的噪声很大,商场中出现了各功能区温度分布不均的现象,原因是送回风口空气流动不畅通,所以管理人员对风系统和水系统的定期检修很重要。因为管路系统中的水或空气都是携带冷量或热量的介质,它们从系统中泄露就直接造成了能量的损失,经常对管道设备进行检查并采取相应的措施是很有必要的。在一些保温管道表面,如果泄露的水打湿了保温材料,就会大大降低保温性能,造成能量损失。同样换热设备的结垢也会造成设备性能的下降,因此,需要对水进行必要的处理和对水系统进行合理的清洗。当风系统过滤器上截留的杂物过多时,阻力升高,导致风机压力上升、能耗增加,并且增加了漏风的可能性,应时常对其进行清洗或更换。

除了以上提到的改造措施以外,还可以根据实际的能耗情况对大型商场的其他组成部分进行改造,达到节能降耗的目的,如对冷却塔进行变频控制,根据实际的负荷调节冷却塔风机转速等。

商场节能管理范文3

[关键词] 照明节电

一、引言

近几年,随着我国商业企业的飞速发展,商场内外照明标准、照明亮度及外部夜景照明显著提高,商场照明用电量每年都以较大的速度提高,而我国发电量的增长则相对滞后,因此,对商场照明节电的要求十分迫切。照明节电就是在保证照度的前提下,推广高效节能照明器具,提高电能利用率,减少用电量。大型商场可从以下方面实施节

电。

二、根据照明要求,选用合适的电光源

在绝大多数情况下,电光源是体现高效节能照明的核心和主体,因此,正确合理地选用电光源,是节能的关键。常用的电光源按发光原理一般分为热幅射电光源如普通照明白炽灯、卤钨灯等。另一类是气体放电光源,如汞灯、钠灯、水银灯、金属卤化物灯等。各种光源的性能参数各不相同。其比热率有较大差异,气体放电光源比热幅射电光源高得多。一般情况下,可逐步用气体放电光源替代热幅射电光源,并尽可能选用光效高的气体放光源。

三、选择高效率的照明灯具

灯具的主要功能是合理分配光源幅射的光通量,满足环境和作业的配光要求,并且不产生眩光和严重的光幕反射。选择灯具时,除考虑环境光分布和限制眩目的要求外,主要考虑灯具的效率,灯的效率用灯的损耗功率(灯功率)除灯的全光通量得到的数值表示,此值越大效率越高。各种光源的灯的效率见图。

在保证照明要求的情况下,各种灯的选用应遵循以下原则:

1.用钨灯取代普通照明白炽灯

可采用各种结构形式不同的卤钨灯取代普通白炽灯。

2.用紧凑型荧光灯取代白炽灯

紧凑型荧光灯的发光效率为普通照明白炽灯的5位~8位以上,其额定寿命是白炽灯的10倍。由于荧光灯的质量的不断提高和改进,紧凑型荧光灯的显色指数可以达到80左右,完全可以满足一般照明的要求。

用紧凑型荧光灯取代普通照明白炽灯节电效果测试数值如下(取代后照度相同)

3.用直管型荧光灯取代白炽灯,采用直管型荧光灯的升级换代产品

直管型荧光灯的光效和寿命均为普通白炽灯的5倍以上,是取代普通白炽灯的最佳灯种之一。用直管型荧光灯取代广泛应用于商业、学校、中小会议室以及家庭照明的白炽灯,显然能大幅度降低电耗。

荧光灯发明于1939年,半个多世纪以来,荧光灯得到了迅速的发展,直管型荧光灯不断升级换代。如功率40W的直型荧光灯,光效从每瓦60流明提高到104流明,从T12发展到T8和近几年出现的T5。光效寿命有显著提高,管径越来越小。积极提倡和鼓励采用与电子镇流器相配使用的直管型荧光灯。

下表给出了T12到T5的直管型荧光灯发光效率的变化:

4.大力推广高压钠灯和金属卤化物灯的应用。

高压钠灯和金属卤化物灯,同属高强度气体放电光源。高压钠灯和金属卤化物灯是取代高压汞灯的最佳选择。

HID灯的正确选择

四、合理选择照度和照明方式

在满足标准照度的条件下,节约电力,应恰当地选用一般照明、局部照明、混合照明三种方式,充分发挥照明效果。一般情况下,当一种光源不能满足显色性要求时,可采用两种以上光源混合照明的方式,这样既提高了光效,又改善了显色性。另外,科学地安排光源分布,能获得满意的光照分布,更好地利用光能量。充分利用自然光,正确选择自然采光,也能改善工作环境,使人感到舒适,有利于健康。

五、选择与光源相匹配的高效节能电器

在商场内照明和室外照明设计中,重视采用各种节能照明电器配件。如采用节能式镇流器、启动器、触发电源、补偿电容器等。

传统式电感镇流器自身功率损耗大,其损耗约占灯功率的20%~30%。而新一代节能式电感镇流器自身损耗明显降低,仅为灯功率的12%左右。由于自身功耗的降低,导致其工作温度明显低于传统式电感镇流器。产品本身具有效率高、发热低的优点,既可实现节能又可延长使用寿命,并且可以提高荧光灯系统的发光效果。

六、加强照明用电的管理

企业在合理配置光源的同时,要对职工进行节能教育。减少电能的人为浪费。

七、结语

商场节能管理范文4

关键词:商务建筑;制冷功能;节能环保

Abstract: with the development of economy and society, more and more attention to energy conservation and environmental protection, especially in business building fields. To satisfy the business building refrigeration function at the same time, how to realize the green refrigeration and energy conservation and environmental protection problem has become the developers and users issues of concern. Based on the business building refrigeration function and the realization of the function of saving energy and environmental protection as the object, the paper analyzes present business building refrigeration function of saving energy and environmental protection against the existing problems, and to the questions some Suggestions to solve them.

Keywords: business building construction; Refrigeration function; Energy conservation and environmental protection

中图分类号: TB657文献标识码:A文章编号:

当今世界对能源的需求越来越大,各国对能源节约问题也越来越重视。我国是一个能源消耗大国,节能是我国的重要国策之一。在所有能耗中,建筑能耗又占有很大比重,在我国,建筑能耗(包括建材生产、建造能耗、生活能耗、空调能耗等)约占中国建筑总能耗的三分之一左右,建筑业的二氧化碳排放量占中国碳排放量同样达到43.7%,且我国建筑中能达到国家新建建筑节能50%标准的建筑也只占同期建筑总量的10%。我国节能工作与发达国家相比起步较晚,尤其在商业建筑领域,能源浪费十分严重,做好我国建筑领域尤其是商务建筑领域的节能环保显得至关重要。

一、我国商务建筑制冷系统节能现状

能耗问题严重制约着我国经济集约化的发展,而商业性建筑作为建筑中的重要方面,在能源消耗中充当着主力军。随着改革开放和经济发展,我国商业建筑的面积日趋增大,据统计目前已经建成大约2000多幢高级宾馆和写字楼,800多家大型商场,设有中央空调系统的建筑面积约1.5亿平方米。商业建筑能源消耗约占总能源消耗的15%-20%,其中空调能耗占商业公共建筑总能耗的50~60%,重视商务建筑节能环保已经成为社会发展的应有之义,促进商务建筑实现在制冷系统中的节能环保是实现节能环保中的重要一环。如何在繁华的都市中心建造节能型商业建筑,对于我国建筑行业发展具有重要意义。

从我国目前商业建筑的使用状况来看,一般情况下,大型商业建筑(存在使用特殊设备的建筑除外),主要的能耗主要集中在中央空调系统、照明系统、冷热水系统、动力系统以及其他方面。从这些使用系统进行区别,设计商业建筑制冷功能的系统则就占了中央空调系统、冷热水系统以及动力系统和其他方面这四个维度。就上海地区而言,据调查,照明系统能耗仅为10%—20%,而空调系统和其他动力系统能耗综合达到70%—90%,而其中设计制冷功能的能耗达到一半左右,制冷功能所表现出的能耗相当可观,如果对其加以控制,将会实现很大程度上的节能环保功能,控制商业建筑制冷功能能耗在商业建筑设计中是必须进行详尽考虑的。

二、商务建筑制冷功能节能的重要意义

1.商务建筑制冷功能节能任务艰巨

《中国建筑节能年度发展研究报告2010》中对我国各类建筑能耗进行了调研,并给出了写字楼、商场、宾馆的能耗调研结果,其中商场的空调系统能耗占比达到50%,而酒店空调能耗占比达到44%,从制冷功能角度而言,其中蕴含巨大节能潜力。

由于商业建筑本身所具备的多种功能,其是区别于其他建筑群体的综合性建筑,且其在使用中往往会出现租赁、销售、外包等多种形式,因此在管理中会存在很多困难,要促进商业建筑的节能减排工作存在复杂性。同时,对于商业建筑制冷功能在南方、北方的区别,节能现状也是有所不同,在协同考虑各地的资源条件、经济社会条件,实现商业建筑节能设计任务艰巨。

2.节能环保是经济、社会发展重要举措

国家对节能减排的大力推进,是当前到2015年节能服务行业发展的巨大力量。节能服务在建筑、交通、空调、注塑机等多个领域内市场空间巨大,建筑中仅中央空调系统就占到建筑能耗的40%左右。

“十二五”期间,公共建筑被确定为节能降耗主要领域。按照日前公布的《财政部、住房城乡建设部关于进一步推进公共建筑节能工作的通知》要求,国家将启动一批公共建筑节能改造重点城市,住建部已初步确定全国近40座城市作为“十二五”期间公共建筑节能改造重点城市,要求每个城市未来两年内完成改造建筑面积不少于400万平方米。

三、商务建筑制冷系统节能环保存在的问题

1.空调制冷系统能耗高、技术落后

空调制冷系统的能耗主要表现在两个方面,一是为了供给空气处理设备冷量和热量的冷热源能耗;二是为了给房间送风和输送空调循环水,风机和水泵所消耗的电能。

一般情况下,中央空调能耗约占整个建筑总能耗的50%左右,对于商场和综合大楼可能要高达60%以上,中央空调成为商业建筑制冷系统能耗的关键点,但是目前我国大部分商业建筑中央空调系统设备技术较为落后,多为老旧设备,大部分未能达到国家能耗标准要求,而且大部分情况下中央空调的存在将会增加其他方面的负荷,进一步增加商业建筑能耗。

2.商务建筑制冷系统节能设计存在缺陷

目前我国关于商业建筑的设计重点考察的因素是其外观、内置功能的满足,较少考虑到关于商业建筑制冷系统节能方面的问题,虽然近年来我国在这一方面有所改善,但情况仍不容乐观。商业建筑制冷功能的实现有赖于制冷系统完整的发挥其功能,从外墙设计、内部通风管道设计、门窗设计、顶层设计以及空调系统等的设计都对其作用的发挥有很大影响。但是我国商业建筑设计很少能将各种因素综合进行考量,从而形成良性的循环系统,致使在制冷系统能耗方面存在很大缺陷。

四、商务建筑制冷功能与节能环保“双赢”建议

实现商务建筑制冷功能与节能环保的“双赢”是促进经济、社会发展的重要方面,也是促进能源解决、发展低碳社会的重要举措。为实现商务建筑制冷功能和节能环保的“双赢”,本文在商业建筑节能领域提出以下几点建议:

1.改善空调系统控制,提高设备技术含量

目前,中央空调系统主机和水泵等设备的选型都大于系统实际负荷需求,造成大量的能量浪费。尽管目前针对中央空调节能改造的手段很多,可以采用中央空调自动控制技术、主机房模糊变频控制技术以及新风换气技术等现代化技术对中央空调制冷设备进行良性控制,根据商业建筑实时负荷,调整主机和其他空调设备,在保证室内温度和湿度的前提下,尽可能地节约能源提高设备的技术含量,选用高能效的空调主机,从根本上解决能耗问题,实现节能和环保突破。

2. 提高商业建筑管理人员节能意识

商场应提高管理人员对于制冷系统节能的敏感意识,配备专职的节能管理人员。节能管理人员应该掌握商场内部的能源利用情况,善于发现问题并解决问题,提高能源利用效率。另外,也可请一些有资质的物业管理公司代为管理,因为专门的物业管理公司既有管理经验,也可以提高能源效率。

3.注重设计,实现制冷功能的系统性

注重商业建筑前期建筑设计,对商务建筑的设计需要从系统的角度出发,在设计商业建筑制冷系统时,综合考虑“护结构、暖通空调系统、室内环境系统、建筑给排水系统、建筑电气系统、楼宇自动控制系统以及可再生能源利用和循环利用”等各个方面的因素,并重点将空调系统作为中心设计关键点,以此实现节能环保和制冷功能的“双赢”。

参考文献

1.付小平等.中央空调系统运行管理(第2版).清华大学出版社,2008

2.薛志峰,江亿.北京市大型公共建筑用能现状与节能潜力分析.暖通空调,2004

商场节能管理范文5

关于节能工作总结

今年以来,我局认真贯彻落实市政府节能工作部署,加强了对商贸企业节能工作的指导,完善措施,突出重点,积极推进了商贸领域节能工作。汇报如下:

一、推广节能技术,降低能耗水平。一是大力推广先进适用的节能新技术、新设备和新材料。对新建、改造或扩建的商业项目,特别是大型商业网点设施建设推广采用先进的节能、节水、节材产品和技术,重点是墙体节能系统、门窗、中央空调系统、自动电梯等设施的综合节能应用。二是推广采用绿色照明。推广使用高效节能照明新光源和装置,加大了更新投入,高效照明产品使用率达到了95%,降低了用电高峰期灯峰负荷。三是严格执行空调温度控制标准。各零售企业自觉养成了科学使用空调,节约用电的良好风尚。特别是大中型商场、超市严格执行空调温度控制标准,夏季室内空调温度设置不低于26摄氏度,冬季室内空调温度设置不高于20摄氏度。四是加强了对主要设施、设备的节能管理。逐步淘汰了能耗高的老旧设备,降低了用电损耗,主要用能设备改造更新率达到了55.5%。重点加强了自动电梯、扶梯的管理,按照客流情况,合理使用。指导企业有效整合物流资源,减少车辆空驶率,降低了物流成本。1至12月份,批发零售业和住宿餐饮业万元营业额能耗同比下降10.5%。

二、规范经营行为,倡导科学消费。一是积极发挥零售企业对消费行为的引导作用,大力倡导节约风尚,在华北商厦、同天购物中心、意明购物中心推行节能标签制度,引导消费能源资源节约型产品,严禁控制不合格的高耗能商品进入商场销售,抑制过度包装商品。认真落实了《商品零售场所塑料购物袋有偿使用管理办法》,减少了一次性塑料袋的使用。二是倡导餐饮企业提供大、中、小份量菜品服务,本着“吃好、吃饱”不浪费的原则,以人定量,引导消费者合理科学用餐,节约饮食,节约资源,倡导形成崇尚节俭、适度消费的文明节约的消费行为。三是在餐饮服务业大力提倡节能高效的管理体系,督促企业更新经营理念,引导教育员工提高节能降耗的意识,建立了专门的领导班子及管理体系,行之有效地监控企业经营的各个环节,通过推广应用节能、节水型产品和技术,最大限度地达到节约用电、用水、用气、用暖的效果。以教育培训为主,增强了员工的节能增效意识,制定了行之有效的管理措施,形成了新的节能降耗的管理体系。

三、强化宣传教育,提高节能意识。积极配合节能办开展了节能宣传周活动,各商贸企业门前悬挂了宣传标语,制作了商贸领域节能宣传展牌,发放节能宣传单3000余份。。6月11日至17日,我局组织同天购物中心、华北商厦开设了节能专柜,设立专人讲解节能知识,宣传节能政策,参与了接受媒体采访、停开电梯1小时节能体验等活动。

明年重点抓好以下工作:

一、推进重点行业节能降耗。认真落实沧州市节能工作要求,根据商业和餐饮服务业不同行业能耗情况,制订我市大型商业设施能耗标准体系,抓好行业的节能降耗工作,力争耗能技术、设施改造更新率达55%以上,高效照明产品使用率达到9!6%,批发零售业和住宿餐饮业万元营业额能耗比上年降低11%。

二、抓好重大技术改造项目。发挥好科技进步在促进商贸流通领域节能降耗的重要作用,努力抓好一批影响力、带动性强的技术改造项目。指导企业在新建、改建、扩建中积极推广建筑节能技术,开发利用太阳能、浅表地热等能源。推广采用节电、节水、节材、节油的技术和产品,对采暖、空调、通风、照明等大型耗能设备设施,采用变频、无功补偿、三相平衡等新技术加快技术改造。

三、大力发展节约型服务业。进一步引导住宿、餐饮等服务业企业推广使用节能技术和产品,减少一次性产品使用,积极开展对用水、用电、用气等节能设施设备进行技术改造。大力倡导餐饮业提供大、中、小份量菜品服务。制定行之有效的管理措施,形成新的节能降耗的管理体系,指导酒家酒店争创国家级绿色饭店。

商场节能管理范文6

【关键词】公共建筑;空调温度;热舒适;节能

中图分类号:TU831.3+5文献标识码: A 文章编号:

一、前言

多年以来,我国公共建筑的空调管理比较粗放,空调温度设置不尽合理,导致能效不高,造成能源资源浪费,增加了环境压力,与建设资源节约型、环境友好型社会的目标不相适应。实践表明,合理设置空调温度,科学管理空调的运行,既能提供比较健康、舒适的室内环境,满足正常的工作、生活和学习需要,又能节约能源,保护生态环境,是一件利国利民的好事。加强空调使用环节的节能环保工作,已日渐成为世界各国的普遍共识和通行做法。我国人口多、底子薄,节约能源资源、保护生态环境的任务十分艰巨,目前节能减排的形势十分严峻。今年夏季用电高峰即将来临,各地区、各有关部门一定要提高认识,提前谋划,加强组织领导,采取有效措施,切实做好空调节能工作。

二、公共建筑空调温度与热舒适

公共建筑空调的室内空气基本参数主要是根据人体舒适感要求来确定。(GBJ19―87)中规定:民用建筑夏季空调温度为24℃ ~28℃ ,冬季空调温度为18℃ ~22℃ 。但是,目前许多从事空调系统设计和运行的人员认为夏季室内空气温度越低,冬季室内空气温度越高则热舒适程度越好。在实际设计和运行中,夏季选取现行规范的最低值,甚至超出规范下限,冬季尽可能取现行规范的最高值,甚至超出规范上限,这不但造成能源的浪费,也不利于人体的热舒适感觉。对于公共建筑夏季和冬季的空调温度的确定,应综合考虑影响热舒适多方面因素。影响公共建筑空调温度的热舒适程度,不但与湿度、风速有关,而且与当时的室内外温差有关,与人们在公共建筑人体衣着薄、厚有关等。

1.热舒适度调查

本次热舒适度调查夏季是针对南昌某六层楼商场进行,该商场的营业时间为10:00~22:00;冬季是针对某高校俱乐部进行。调查内容包括热舒适度主观调查和空调温度的现场测试。

夏季,现场空调温度的测试是在商场的一楼和三楼进行,测试时间是2002年7月13日,当时室外最高气温为36℃,测试结果其温度变化曲线如图1,从图中可知,该商场一楼的空调温度为23.5℃~25.6℃;而三楼的空调温度为21.4℃~24.0℃。主观调查是直接面对顾客进行,通过对100名顾客的询问,得出商场空调热舒适度统计结果为: 图1 南昌某商场室内沮度变化14%的顾客认为热舒适度很好;33%的顾客认为热舒适度适中;48%的顾客认为空调温度偏低;5%的顾客认为空调温度偏高。

冬季,对某高校俱乐部热舒适度进行调查,时间是2002年12月26日,当时室外最高气温为4℃,室内空调温度经测试为25℃。通过观察和调查发现人员有三分之一表现出神疲力乏、昏昏欲睡;有三分之二认为室内空调温度过高,精力难以集中,并且走出俱乐部时很不适应。

2.人体衣着、空调温度与热舒适

从Fanger舒适方程可知,影响人体热舒适程度与人的衣着和活动量有关。夏季室外气温较高,天气炎热,人们出入一些公共场所时,大多数人穿一般的夏季服装,其衣服热阻为0.5clo,对于不同的人体能量代谢率的公共建筑,其最舒适的工作温度不同,见图2。

在图书馆,人体能量代谢率为1.0met,其最舒适的工作温度为26℃ 。然而,图2中最舒适的工作温度并未考虑人们出入时人体表面温度对人体的影响,由于公共建筑是人们出入的短期停留场所,所以出入时人体表面温度对人体的影响必需加以考虑。对于刚从室外进入公共场所的人们,由于室外气温较高天气炎热,其衣服表面温度较高(如当室外气温为34℃ 时,其衣服表面温度约为36℃),并且当室内温度低于26℃时,人体表面与室内温差高达10多度,此时,大温差和汗水蒸发使人体的体温调节功能受到影响,人们感觉室内温度偏低,甚至容易诱发感冒及呼吸道疾病。因此夏季公共建筑的空调温度应取室内舒适温度偏高值。

冬季室外气温较低,天气寒冷,人们出入一些公共场所时,大多穿厚外衣,其衣服热阻为1.6clo,对于不同的人体能量代谢率的公共建筑,其最舒适的工作温度不同,见图3。

在商场,其人体能量代谢率为1.6met,其最舒适的工作温度为14℃;然而在实际设计和运行中,普遍将温度设在20℃ 以上,这样一来导致衣服表面温度与环境的温差就很小,人体热量散发也就很小,所以人就会感觉室内温度偏高。另外,据生理学家研究,室内温度过高时,会影响人的体温调节功能,如果室内温度经常保持在25℃以上,人就会神疲力乏、头晕脑涨、思维迟钝、记忆力差等。所以冬季公共建筑的空调温度应取室内舒适

温度偏低值。

3.室内外温差与热舒适

公共建筑室内空调温度的设置,必须考虑室内外温差的影响,近几年的研究表明,在夏天当室内外温差超过10℃时,人们容易感冒。冬季室内温度不宜过高;而夏季室内温度不宜过低。对于炎热地区的公共建筑室内外的温差取7℃ 左右最为适宜。

三、公共建筑空调温度的确定与节能

对于公共建筑夏季和冬季的空调温度确定,既要考虑热舒适,还要考虑节能因素。目前我国建筑耗能年平均递增率已大大超过国家能源生产年增长率,节能是我们面临的一个突出问题。通过适当降低冬季室内设计温度和提高夏季室内设计温度,在围护结构和室外计算参数一定的条件下,供暖时,室内温度每降低1℃,耗能量可减少10%~15%;供冷时,每提高1℃可节能10%左右 。

1.降低室内空调参数标准

进行空调设计应结合公共建筑使用特点,可以适当降低室内空调参数标准,不能盲目套用国外数据或不顾国情而盲目追求高标准。近年来为了节能,国外也在修改或降低标准,如美国等发达国家对一些公共建筑室内空调设计参数的最高标准作了限制。以夏季室温26℃,相对湿度65%,冬季室温20℃,相对湿度40%作为空调供冷和供热的最高标准。所以在实际设计和运行中,对于炎热地区的公共建筑空调温度,夏天设定为26℃以上;冬天设定为18℃以下。这样一来既可以减小室内外温差,满足公共建筑的热舒适要求,又可以达到节能的目的。

2.改变空调温度的设定值

公共建筑大多数是休闲娱乐场所,人们经常利用工作外的闲余时间出入公共场所,所以公共建筑会形成节假日情结,节假日中人员多、客流量大、就座率高。因此,对于公共建筑空调温度应根据客流量的大小进行调节。这不但可以改善建筑的热舒适度,而且还能达到良好的节能效果。如电影院就座率变化很大,可以根据就座率来调节室内空调温度,冬季就座率高,空调温度可以适当降低;夏季就座率低,人体的辐射换热增强,空调温度可以适当提高。

3. 严格执行空调监督管理和空调能效标识制度

将实施公共建筑空调温度控制标准纳入节能减排丁作目标责任体系,建立和完善工作机制,依法对公共建筑空凋温度控制情况开展节能监察和监测,定期对机关办公楼、宾馆、写字楼、商场超市等空调使用大户室内温度进行抽查检测。严肃查处违法违规行为,逐步将家用空调能效水平全部从5级达到1级,严禁不合格的高耗能空调进入市场。

四、结束语

合理设置空调温度,科学管理空调的运行,既能提供比较健康、舒适的室内环境,满足正常的工作、生活和学习需要,又能节约能源,保护生态环境,是一件利国利民的好事。我国人日多、底子薄,节约能源、保护环境是每个公民的义务和责任。目前节能减排的形势十分严峻,我们要进一步落实《国务院关于加强节能工作的决定》精神,促进科学使用空调,节约能源资源,减少温室气体排放,有效保护环境。

参考文献

[1]陈鹏 实施公共建筑空调温度控制的主要措施能源与环境-2009年4期

[2]王艮 上海市对高温期间空调温度进行执法检查制冷-2008年4期

[3]廖婉玲 重庆市电力公司带头节能保供电电力需求侧管理-2008年5期